Steel Conduit System is a closed wiring system consisting of conduits and conduit fittings for the protection and management of insulated conductors, electrical cables or communication installations, allowing them to be drawn in and/or replaced, but not to be inserted laterally. Calaba provides a wide range of metallic conduit and conduit fittings for concealed, surface wiring for electrical, Tele communication appliances for all type of projects.
Steel Conduit Pipe
Standard Compliance
Standard Compliance
| CODES | STANDARD COMPLIANCE |
|---|---|
| BS EN 61386-1 (BS EN 50086-1) | Conduit systems for cable management — Part 1: General requirements. |
| BS EN 61386-21 (BS EN 50086-21) | Conduit systems for cable management. Part 21. Particular requirements. Rigid conduit systems. |
BS EN 61386-21-Class 3 Steel Conduit
• Heavy protection on exterior and medium protection on interior of conduit surface
• Threaded at both ends, one end is fixed with socket and other end comes with protective plastic cap.
| Nominal size (mm) | Outside Diameter (mm) Colour | Wall Thickness (mm) | Length of thread | Weight per Length (kg) | ||
| Min | Max | Min | Max | |||
| 20 | 19.7 | 20.0 | 1.6±0.15 | 13.0 | 15.0 | 2.7kg |
| 25 | 24.6 | 25.0 | 1.6±0.15 | 16.0 | 18.0 | 3.4kg |
| 32 | 31.6 | 32.0 | 1.6±0.15 | 18.0 | 20.0 | 4.5kg |
Note: • Standard length 3.75 m • Customized colour finishing available based on request
BS EN 61386-21-Class 4 Steel Conduit
• Heavy protection on exterior on interior of conduit surface
• Threaded at both ends, one end is fixed with socket and other end comes with protective plastic cap
| Nominal size (mm) | Outside Diameter (mm) Colour | Wall Thickness (mm) | Length of thread | Weight per Length (kg) | ||
| Min | Max | Min | Max | |||
| 20 | 19.7 | 20.0 | 1.6±0.15 | 13.0 | 15.0 | 2.9kg |
| 25 | 24.6 | 25.0 | 1.6±0.15 | 16.0 | 18.0 | 3.8kg |
| 32 | 31.6 | 32.0 | 1.6±0.15 | 18.0 | 20.0 | 5.5kg |
Note: • Standard length 3.75 m • Customized colour finishing available based on request
Steel & PVC COATED FLEXIBLE CONDUIT
| Material | : | Electro-Galvanized steel and Thick PVC sheath |
| Construction | : | Highly flexible and provide strong protection |
| Temp Range | : | -50 deg C to+350 degC |
| IP Rating | : | IP40 |
| Standard | : | BS 731-1/BS EN 50086-1/BS EN 61386-1 |
| Item Description | Diameter | Length |
| Steel Flexible | 16mm | 15m |
| 20mm | ||
| 25mm | ||
| 32mm | ||
| 38mm |
| Item Description | Diameter | Length |
| PVC Coated GI Flexible |
16mm 20mm 25mm |
30m |
|
35mm 38mm |
25m | |
CIRCULAR JUNCTION BOX
CIRCULAR JUNCTION BOX is conduit fitting with a removable cover designed to join or terminate one or more components of a conduit system.
1 WAY TERMINAL BOX
2 WAY TERMINAL BOX
2 WAY ANGLE TERMINAL BOX
3 WAY ANGLE TEE BOX
4 WAY CROSS BOX
| Item Description | Size | Packaging |
| Circular Junction Box | 20mm | 10/100 Pack/CTN Qty |
| 25mm | 10/100 Pack/CTN Qty | |
| 32mm | 5/10 Pack/CTN Qty |
SWITCH & SOCKET BOXES
It is part of an enclosure provided with means for fixing a cover, cover plate, accessory, etc, and intended to receive socket outlets with portion of the side or back of a box which can readily be removed when required.
ACCESSORIES
Steel Conduit System is a closed wiring system consisting of conduits and conduit fittings for the protection and management of insulated conductors, electrical cables or communication installations, allowing them to be drawn in and/or replaced, but not to be inserted laterally. Calaba provides a wide range of metallic conduit and conduit fittings for concealed, surface wiring for electrical, Tele communication appliances for all type of projects.
Steel Conduit Pipe
Standard Compliance
| CODES | STANDARD COMPLIANCE |
|---|---|
| BS EN 61386-1 (BS EN 50086-1) | Conduit systems for cable management — Part 1: General requirements. |
| BS EN 61386-21 (BS EN 50086-21) | Conduit systems for cable management. Part 21. Particular requirements. Rigid conduit systems. |
BS EN 61386-21-Class 3 Steel Conduit
• Heavy protection on exterior and medium protection on interior of conduit surface
• Threaded at both ends, one end is fixed with socket and other end comes with protective plastic cap.
| Nominal size (mm) | Outside Diameter (mm) Colour | Wall Thickness (mm) | Length of thread | Weight per Length (kg) | ||
| Min | Max | Min | Max | |||
| 20 | 19.7 | 20.0 | 1.6±0.15 | 13.0 | 15.0 | 2.7kg |
| 25 | 24.6 | 25.0 | 1.6±0.15 | 16.0 | 18.0 | 3.4kg |
| 32 | 31.6 | 32.0 | 1.6±0.15 | 18.0 | 20.0 | 4.5kg |
Note: • Standard length 3.75 m • Customized colour finishing available based on request
BS EN 61386-21-Class 4 Steel Conduit
• Heavy protection on exterior on interior of conduit surface
• Threaded at both ends, one end is fixed with socket and other end comes with protective plastic cap
| Nominal size (mm) | Outside Diameter (mm) Colour | Wall Thickness (mm) | Length of thread | Weight per Length (kg) | ||
| Min | Max | Min | Max | |||
| 20 | 19.7 | 20.0 | 1.6±0.15 | 13.0 | 15.0 | 2.9kg |
| 25 | 24.6 | 25.0 | 1.6±0.15 | 16.0 | 18.0 | 3.8kg |
| 32 | 31.6 | 32.0 | 1.6±0.15 | 18.0 | 20.0 | 5.5kg |
Note: • Standard length 3.75 m • Customized colour finishing available based on request
Steel & PVC COATED FLEXIBLE CONDUIT
| Material | : | Electro-Galvanized steel and Thick PVC sheath |
| Construction | : | Highly flexible and provide strong protection |
| Temp Range | : | -50 deg C to+350 degC |
| IP Rating | : | IP40 |
| Standard | : | BS 731-1/BS EN 50086-1/BS EN 61386-1 |
| Item Description | Diameter | Length |
| Steel Flexible | 16mm | 15m |
| 20mm | ||
| 25mm | ||
| 32mm | ||
| 38mm |
| Item Description | Diameter | Length |
| PVC Coated GI Flexible |
16mm 20mm 25mm |
30m |
|
35mm 38mm |
25m | |
CIRCULAR JUNCTION BOX
CIRCULAR JUNCTION BOX is conduit fitting with a removable cover designed to join or terminate one or more components of a conduit system.
1 WAY TERMINAL BOX
2 WAY TERMINAL BOX
2 WAY ANGLE TERMINAL BOX
3 WAY ANGLE TEE BOX
4 WAY CROSS BOX
| Item Description | Size | Packaging |
| Circular Junction Box | 20mm | 10/100 Pack/CTN Qty |
| 25mm | 10/100 Pack/CTN Qty | |
| 32mm | 5/10 Pack/CTN Qty |